Seitenansicht 17
Envoy Installation and Operation
Copyright 2012 Enphase Energy 141-00011 Rev 03
18
Above the Levelindicator the LCD screen displays brackets enclosing zero to five
bars.
NOTE: Until microinverters are detected, the Level indicator shows no bars.
Signal strength is acceptable if three to five bars are displayed and all devices are
accounted for. One to two bars may not be effective for consistent communication.
3. If, after 15 minutes, fewer than three bars are displayed, refer toPower Line
Communication Troubleshootingon page 24.
Remaining minutes and seconds in Comm Check are displayed (“mm:ss” in the
example). The “Devices” counter displays the number of microinverters detected and
will increase until all microinverters are detected. Ultimately, the number of
microinverters detected should match the number of installed microinverters.
4. After 20 minutes, the communication check automatically stops. If you want to end the
communication check before it times out, press and hold the menu button to activate
the Envoy menu. When “Disable Communication Check” displays, release the menu
button.
Initiating a Scan for New Microinverters
If you add additional microinverters to an existing system or replace a microinverter, you will need
to run a scan to detect the new devices. To initiate a scan after you add new microinverters to an
existing Enphase system perform the following steps.
Alternatively, you can initiate a scan through the administration page when connected to the Envoy
local interface with a computer, or via Enlighten (Refer toUsing Enlighten to Check Envoy Status
on page 23).
1. Press and hold the Envoy Menu button; after two seconds the Envoy menu appears.
2. Continue holding the Menu button. When the LCD screen displays “Enable New Device
Scan”, release the Menu button.
The LCD screen then reads:
Device scan active
for 00d:00h:30m
Enable
New Device Scan