Envoy Installation and Operation
Copyright 2012 Enphase Energy 141-00011 Rev 03
13
Envoy Operation
First Scan for Microinverters
A newly installed Envoy automatically performs an initial scan to discover all of the microinverters
that are installed and powered up at the site. This initial scan continues to search for new
microinverters for seven days from initial start up of the Envoy. The purpose of this long scanning
period is to account for additional microinverters that may be installed during this initial seven-day
time frame. This one-time process is not repeated. During the scan, you will notice some values
increasing on the Envoy display.
NOTE: If you power up the Envoy, even for just a few minutes, the seven-day scan
begins at that point. If you then power it back down and leave it off until you are ready
to discover the microinverters, the initial scan may have expired. A new scan can be
initiated, and will be required if the installation is done in stages over more than seven
days. The steps for initiating a new device scan are described on page
18 of this
manual.
The Envoy identifies each device by its unique serial number. If a microinverter is ever added or
replaced at the site, you must initiate a new scan so that the Envoy can discover the new
microinverter. The steps for initiating a new device scan are described on page 18 of this manual.
After the Envoy has detected at least one new device, it will automatically enter Priority Scan mode.
The LCD screen will display the following, where “nnnn” represents the number of microinverters
(devices) detected.
NOTE: No power production data will be collected or displayed on the Envoy or in
Enlighten while Priority Scan is active. Also, the Communication Check function will not
operate during this period.
When the Envoy does not detect a device during a polling interval (usually 5 minutes), it will exit
Priority Scan mode. If, subsequently, the Envoy detects another device, it will return to Priority Scan
mode. It will remain in this mode until it again completes an interval where no devices are
detected.
LCD Screen Displays at Start Up
After a power outage or Envoy shut down, it takes less than five minutes for the Envoy to be ready to work
after reapplying power. This five-minute period is known as a boot sequence. You will know the Envoy
has completed booting and has started normal operation when it displays both an IP address and the
“+Web” status indication in the LCD screen.
Priority Scan is
Active Devs: nnnn