Envoy Installation and Operation
2013 Enphase Energy Inc. 141-00011 Rev 05
22
1. Press and hold the Menu button on the right side of the Envoy to bring up the Envoy menu on
the LCD screen.
2. When the LCD screen displays “Enable Communication Check”, release the Menu button.
The LCD screen then reads:
The Envoy begins a 20-minute communications check to assess the signal strength between
the Envoy and the microinverters detected at the site. Until the Envoy begins detecting
microinverters, the display reads:
NOTE: The communications check displays communication levels for devices already in
the Envoy database; it does not scan for new devices.
When the Envoy begins detecting microinverters, the display shows power line
communication Level and Device count:
To the right of the word “Level”, you’ll see brackets enclosing zero to five bars. The example
above shows three bars.
NOTE: Until microinverters are detected, the Level indicator shows no bars.
Signal strength is acceptable if three to five bars are displayed and all devices are accounted
for. One to two bars may not be sufficient for consistent communication.
3. If, after 15 minutes, fewer than three bars are displayed, refer to “Power Line Communication
Troubleshooting” on page 28.
The “Devices” counter displays the number of microinverters detected and will increase until
all microinverters are detected. Ultimately, the number of microinverters detected should
match the number of installed microinverters.
4. After 20 minutes, the communications check stops. To stop the communications check before
it times out, press and hold the menu button to activate the Envoy menu. When “Disable
Communication Check” is displayed, release the menu button.
Level: [ ]
Devices: 25
Communications check
Searching Devices
Comm check enabled
for 20min
Enable
Communication Check